Filter Results By:

Products

Applications

Manufacturers

Showing results: 31 - 45 of 58 items found.

  • Digital Arrester Clamp Tester (with Data output)

    ALCL-40H - MULTI MEASURING INSTRUMENTS Co., Ltd.

    *ALCL-40 is designed to test the diagnostic of OXIDE SURGE ARRESTER.*The least influence from the external magnetic field and noise by triple shielding of CT.*Compliant with IEC6099-5.*Enabled the measurements for 100nA resolution and harmonics current.

  • IGNITION COIL TESTER - ORANGE

    MD76500M - Matco Tools

    *Non-intrusive, quick check tool instantly verifies active or inactive coil operation*Detects the magnetic field created by a coil energizing*Tool can be used to test coil on plug, coil near plug and coil pack systems

  • Vacuum Interrupter Testers

    Vacuum Interrupters, Inc.

    Until now, the accepted field service test for vacuum interrupters has been a simple Go/No-Go test performed with an AC high potential test. Today, testing with our Magnetic Atmospheric Condition (MAC) test sets can prevent unnecessary damage to your circuit breakers and contactors by predicting the usable life of the vacuum interrupter.

  • Hearing Aid Compatibility Automated Test System

    MiNi-HAC - APREL, Inc.

    Hearing Aid Compatibility (HAC) evaluation of wireless handsets ensures accessibility of these technologies to the hearing impaired. The MiNi-HAC system can be used for the design and development of wireless handsets as well as for evaluation of hearing aids used by the hearing impaired to gain access to mobile wireless technologies. RF Emissions Test - near field measurements of the electric and magnetic fields emitted by a wireless device.

  • Magnetic Particle Flaw Detector

    MT-1A - Mitech Co., LTD.

    MT-1A digital portable magnetic flaw detector, adopts large capacity lithium battery power supply. DC is exchanged into AC by the inverter and the phase shifted signal processor to provide power for the detector, it solves the shortcomings of traditional magnetic particle detector relying on the 220V power supply. It has low power consumption and can continuous work for more than 4 hours. The battery can be charged while working or off. It can real-time monitoring, process image, save data, print the test report, track inspection results, meet the requirements of standard operation and management. Especially suitable for the field without power supply field testing and high-altitude operations, it realizes the innovation of magnetic powder digital inspection.

  • Shielding Effectiveness/ Conductivity Test

    EM-2107A | 30 MHz – 1.5 GHz - Electro-Metrics Corp.

    The EM-2107A is a standard test fixture for evaluation of the electromagnetic shielding effectiveness of planar material. The fixture is an enlarged section of coaxial transmission line and complies fully with the requirements of ASTM test method D4935-1. The measured data relates to the shielding effectiveness due to a plane wave (far field EM wave) from which near field values for magnetic and electric fields may be inferred. The EM-2107A is provided with a reference standard test specimen, a dynamic range specimen. Dynamic range of greater than 80dB is achievable, although the cables and other test system components usually establishes the limiting factors.

  • Gaussmeter

    DX-101 - Dexing Magnet Tech. Co., Ltd

    DX-101 Gaussmeter is based on the Hall effect magnetic field strength of the latest developments in instrumentation, the design of desktop-type Gauss meter. Maximum range 330.0mT and 3000mT two tranches, the minimum basic error of 1.0%. Test probe connectors is imported, stable and reliable connection.

  • Single Sheet Tester

    Model SST500X500 - Gopal Electronics

    Gopal Make single sheet tester SST is developed as per IEC 60404-3. It can be attached as probe to Ep400 Main unit and user can test specific total loss, specific apparent power, and r.m.s value of magnetic field strength as well as B/h curve in the software.

  • Test Fixture, Shielding Effectiveness

    EM-2108 | 1.5 GHz – 10 GHz - Electro-Metrics Corp.

    The EM-2108 is a standard test fixture for evaluation of the electromagnetic shielding effectiveness (SE) of planar materials. The fixture is a section of coaxial transmission line broken to allow the insertion of planar test materials. Although ASTM D4935-10 is currently limited to an upper frequency of 1.5 GHz, the EM-2108 meets and complies fully with both the impedance and SE requirements called out in ASTM test method D4935-10 up to 10 GHz. These results are shown in Figures 1 & 2. The measured data relates to the shielding effectiveness due to a plane wave (far field EM wave) from which near field values for magnetic and electric fields may be inferred.

  • Polarity Tester

    PT-1 - International Electro-Magnetics, Inc.

    The PT-1 provides a simple and easy way to determine the relative polarity of coil windings. It allows for an in-process test that takes a minimum of time to perform. By placing a coil on the platform and making connection to the start and end of a winding, a test signal is induced in the winding. The induced signal is low level and completely safe for the operator. By comparing the test signal phase of the coil under the test output, the relative polarity is indicated by the Red/Green LED. The tester operates by inducing a signal voltage in the coil under test by means of a magnetic flux field. The field is generated by a coil located in the probe base. The coil configuration is designed to provide optimum field distribution. We have also applied this basic circuit to a 5-channel scanning unit.

  • Magnetic Stripe Test Cards

    Barnes International Ltd

    Test Limit Cards (and tickets) are nominally encoded to ISO standards BUT WITH specific parameters deliberately set to predetermined levels, which can be inside or outside the ISO limits. The Test Limit Cards are designed for use by Test\Inspection Departments, Field Service Engineers, Reader \ Encoder Development Engineers to check and confirm proper operation of magnetic stripe reading equipment (e.g. ATMs and POS).

  • Digital Power Transducer

    LP Series - Hsiang Cheng Electric Corp

    *High accuracy 0.07% rd + 0.03% ro*Excellent long term stability*Outstanding over capability and temperature performance*Wide selection of input / output ranges*Meets ANSI C37.90 (1989) and BEAMA No. 219 tests*High magnetic field immunity*Real power - able to measure distorted waveform

  • UtiliShelf®

    The Eastern Specialty Company

    UtiliShelf® (Catalog No. 1063) allows you to create a quick and easy work station at a site. The UtiliShelf® is magnetic and will attach to any metal object (16 gauge or thicker for full magnet strength). No more worrying about where you’ll be setting up your test equipment or laptop in the field!

  • Soft Magnetic Tester

    Model SMT-700 - Magnetic Instrumentation Inc.

    KJS Associates/Magnetic Instrumentation offers the Model SMT-700 computer-automated magnetic test station for measuring the DC and AC magnetization curves, coercive field strength, and core-loss characteristics of magnetically soft materials, including: Si-Fe, Fe-Co, Fe, stainless steel, Ni-Fe alloys, soft ferrites and others. This modern line of laboratory instruments is designed specifically for accuracy, reliability, and ease-of-use.

  • Energy Saving System

    ECO-Vibe neo - EMIC Corporation

    ECO-Vibe neo has been designed for an eco-friendly vibration test system. The test conditions with a vibration test system depends on a unit under test. Generally, the exciting force required for performing a vibration test can be calculated by the product of mass (e.g. test article, jig, table, etc.) and test acceleration. But, when the required exciting force is smaller than the maximum rated exciting force of the vibration test system, the field power supply that the constant current has to be continuously provided to produce the DC magnetic field constitutes a large part of power consumption compared with the drive power for the moving element. ECO-Vibe neo can reduce the power consumption by choosing the exciting force in this case. In addition, you can enjoy a reduction merit of the running cost from the first year when the system is introduced because initial cost is zero.

Get Help